Original Dual Channel Handheld Oscilloscope JDS2022A

Rp4.500.000

Applications suitable for:
1. Vehicle Maintenance
2. Phone Repair
3. Electronic Repair
4. Appliance Repair
5. Research
6. Education
7. Etc

Categories: ,

Description

Original Dual Channel Handheld Oscilloscope JDS2022A

Features
1. Real-time sampling rate of up 200MSa / S, or Quick Response Capture albeit very complicated or complex signal
2. New design ultra-thin, small size, light weight, more convenient to carry, especially suitable for automotive repair shops
3. Color LCD display TFTLCD, 320 * 240 resolution, memngkinkan the waveform display is clearer and stable
4. Single-channel, equipped with a digital multimeter functions that strong sangaat
5. Can save on USB stick
6. Support for USB storage devices and can menyimpat two waveforms at once
7. Supported 6 groups on the internal memory oscilloscopes
8. Type automatically detects a trigger or support (50Hz-40MHz)
9. Support display the time and voltage cursors
10. It could be added wave wave waveform form MACT
11. Display language menu Inglish
12. Template display: the display color, black and white display
13. Supports automatic power off function and a power saving mode: time can be set
14. Backlight brightness can be adjusted
15. Waveforms can be saved screenshot
16. Time siagasiaga: single battery can work continuously for about 5 hours
17. ARM processor + FPGA programmable logic + Chip AD9288 dual high-performance,
18. The performance is very high

Applications suitable for:
1. Vehicle Maintenance
2. Phone Repair
3. Electronic Repair
4. Appliance Repair
5. Research
6. Education
7. Etc

User Manual Download Address:
Google Drive:
https://drive.google.com/file/d/0B8PmY6nhQadKNzRrdF9LTUdxUHc/view?usp=sharing
Dropbox:
https://www.dropbox.com/s/i5d73y4tokdm3bg/JDS2012A%E3%80%812022A%20User%20Manual.pdf?dl=0

Input
Input coupling :AC & DC
Input impedance :1MO 25pF
The maximum input voltage :40V (probe X1); 400V (probe X10) can be measured 220V voltage; (probeX100) 2000V

voltage can be measured
Probe attenuation :1X?10X
Set the probe attenuation factor :1X, 10X, 100X

Signal acquisition system
Sampling Method :Real-time sampling, random sampling
Memory depth :4K (per channel for each 2K)
Acquisition Mode :Sample, Peak Detect

Vertical System
Vertical Sensitivity :10mV-5V (Probe 1X) 100mV-50V (probe 10X) (1,2.5,5 step)
Vertical accuracy :+/-3%
Vertical resolution :8bit
Bandwidth :20MHz

Horizontal Systems
Real-time sampling rate :200 MSa/s
Horizontal scan range :10nS/div-5S/div

Trigger System
Mode :Auto, Normal and Single
Type :Rising edge trigger, falling edge trigger
Automatic detection :Support (50Hz-40MHz)
Math : CH1 + CH2, CH1-CH2, CH2-CH1

Measurement System
Cursor measurement :Support time and voltage cursors
Measurements :Manual
Measure :Peak and frequency

Equipment
Screen :3.2-inch, 16-bit true color, TFT, 320 * 240
Battery :3000 + mA lithium battery (single cell about four hours of continuous work)
Size :202 * 100 * 35 (mm)